An E2B(R3) case is organised in sections: C administrative and identification (C.1 the report, C.2 the primary source, C.3 the sender, C.4 literature references, C.5 the study), D patient, E reactions and events, F tests and procedures, G drugs, H narrative and comments.
The elements that cause the most mistakes:
- C.1.4, date first received: the day the sender first had the four minimum criteria from the primary source. A company retransmitting a case from another company or a regulator uses the date it first received it.
- C.1.5, date of most recent information: changes each time follow-up arrives from a primary source. It does not change when the sender amends the case for another reason, such as an internal review.
- C.1.7, "does this case fulfil the local criteria for an expedited report?": required, true or false, by the sender's local rules. In the EU it is TRUE for any ICSR due within the 15-day or the 90-day time frame.
- C.1.11.1, nullification (1) or amendment (2): an amendment keeps the same case identifiers (C.1.1 and C.1.8.1).